Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 10.070
Filtrar
1.
Sci Rep ; 14(1): 10594, 2024 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719953

RESUMEN

Colorectal liver metastases (CRLM) are the predominant factor limiting survival in patients with colorectal cancer and liver resection with complete tumor removal is the best treatment option for these patients. This study examines the predictive ability of three-dimensional lung volumetry (3DLV) based on preoperative computerized tomography (CT), to predict postoperative pulmonary complications in patients undergoing major liver resection for CRLM. Patients undergoing major curative liver resection for CRLM between 2010 and 2021 with a preoperative CT scan of the thorax within 6 weeks of surgery, were included. Total lung volume (TLV) was calculated using volumetry software 3D-Slicer version 4.11.20210226 including Chest Imaging Platform extension ( http://www.slicer.org ). The area under the curve (AUC) of a receiver-operating characteristic analysis was used to define a cut-off value of TLV, for predicting the occurrence of postoperative respiratory complications. Differences between patients with TLV below and above the cut-off were examined with Chi-square or Fisher's exact test and Mann-Whitney U tests and logistic regression was used to determine independent risk factors for the development of respiratory complications. A total of 123 patients were included, of which 35 (29%) developed respiratory complications. A predictive ability of TLV regarding respiratory complications was shown (AUC 0.62, p = 0.036) and a cut-off value of 4500 cm3 was defined. Patients with TLV < 4500 cm3 were shown to suffer from significantly higher rates of respiratory complications (44% vs. 21%, p = 0.007) compared to the rest. Logistic regression analysis identified TLV < 4500 cm3 as an independent predictor for the occurrence of respiratory complications (odds ratio 3.777, 95% confidence intervals 1.488-9.588, p = 0.005). Preoperative 3DLV is a viable technique for prediction of postoperative pulmonary complications in patients undergoing major liver resection for CRLM. More studies in larger cohorts are necessary to further evaluate this technique.


Asunto(s)
Neoplasias Colorrectales , Hepatectomía , Neoplasias Hepáticas , Complicaciones Posoperatorias , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Neoplasias Colorrectales/patología , Neoplasias Colorrectales/cirugía , Persona de Mediana Edad , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/secundario , Anciano , Hepatectomía/efectos adversos , Hepatectomía/métodos , Complicaciones Posoperatorias/etiología , Pulmón/patología , Pulmón/diagnóstico por imagen , Pulmón/cirugía , Estudios Retrospectivos , Imagenología Tridimensional , Mediciones del Volumen Pulmonar , Factores de Riesgo , Periodo Preoperatorio
2.
Sci Rep ; 14(1): 8119, 2024 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-38582758

RESUMEN

Breathing difficulties and exertional dyspnea are frequently reported in hypermobile Ehlers-Danlos syndrome (hEDS); however, they are not clearly explained. An impaired proprioception or the addition of a cognitive task could influence ventilatory control. How can the perception of lung volume be measured? Is lung volume perception impaired in hEDS patients? Is the breathing control impaired during a cognitive task in hEDS patients? A device was developed to assess the accuracy of lung volume perception in patients with hEDS and matched control subjects. In the second step, ventilation was recorded in both groups with and without a cognitive task. Two groups of 19 subjects were included. The accuracy of lung volume perception was significantly (P < 0.01) lower at 30% of inspired vital capacity in patients with hEDS in comparison to the control group, and they showed erratic ventilation (based on spatial and temporal criteria) when performing a cognitive task. These data support the influence of the proprioceptive deficit on ventilatory control in hEDS patients. These elements may help to understand the respiratory manifestations found in hEDS. Future research should focus on this relationship between lung volume perception and ventilation, and could contribute to our understanding of other pathologies or exercise physiology.Trial registration number: ClinicalTrials.gov, NCT05000151.


Asunto(s)
Síndrome de Ehlers-Danlos , Humanos , Síndrome de Ehlers-Danlos/patología , Pulmón/patología , Disnea , Mediciones del Volumen Pulmonar , Percepción
3.
Respir Res ; 25(1): 155, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38570835

RESUMEN

BACKGROUND: Reference values for lung volumes are necessary to identify and diagnose restrictive lung diseases and hyperinflation, but the values have to be validated in the relevant population. Our aim was to investigate the Global Lung Function Initiative (GLI) reference equations in a representative healthy Austrian population and create population-derived reference equations if poor fit was observed. METHODS: We analysed spirometry and body plethysmography data from 5371 respiratory healthy subjects (6-80 years) from the Austrian LEAD Study. Fit with the GLI equations was examined using z-scores and distributions within the limits of normality. LEAD reference equations were then created using the LMS method and the generalized additive model of location shape and scale package according to GLI models. RESULTS: Good fit, defined as mean z-scores between + 0.5 and -0.5,was not observed for the GLI static lung volume equations, with mean z-scores > 0.5 for residual volume (RV), RV/TLC (total lung capacity) and TLC in both sexes, and for expiratory reserve volume (ERV) and inspiratory capacity in females. Distribution within the limits of normality were shifted to the upper limit except for ERV. Population-derived reference equations from the LEAD cohort showed superior fit for lung volumes and provided reproducible results. CONCLUSION: GLI lung volume reference equations demonstrated a poor fit for our cohort, especially in females. Therefore a new set of Austrian reference equations for static lung volumes was developed, that can be applied to both children and adults (6-80 years of age).


Asunto(s)
Pulmón , Masculino , Adulto , Niño , Femenino , Humanos , Austria/epidemiología , Valores de Referencia , Mediciones del Volumen Pulmonar/métodos , Capacidad Pulmonar Total , Espirometría/métodos , Volumen Espiratorio Forzado , Capacidad Vital
4.
Medicina (B Aires) ; 84(2): 359-363, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38683525

RESUMEN

The apnea test, employed for brain death assessment, aims to demonstrate the absence of respiratory drive due to hypercapnia. The tracheal oxygen insufflation apnea test mode (I-AT) involves disconnecting the patient from invasive mechanical ventilation (iMV) for approximately 8 minutes while maintaining oxygenation. This test supports the diagnosis of brain death based on a specified increase in PaCO2. Common complications include hypoxemia and hemodynamic instability, and lung collapse-induced reduction in end-expiratory lung volume (EELV). In our case series utilizing electrical impedance tomography (EIT), we observed that continuous positive airway pressure during the apnea test (CPAP-AT) effectively mitigated lung collapse. This resulted in improved pulmonary strain compared to the disconnection of iMV. These findings suggest the potential benefits of routine CPAP-AT, particularly for potential lung donors, emphasizing the relevance of our study in providing quantitative insights into EELV loss and its association with pulmonary strain and potential lung injury.


La prueba de apnea es una técnica diagnóstica ampliamente utilizada para la evaluación de la muerte cerebral, con el objetivo de demostrar la ausencia de impulso respiratorio debido a la hipercapnia. La variante de la prueba de apnea con insuflación de oxígeno traqueal (I-AT) implica desconectar al paciente de la ventilación mecánica invasiva (iVM) durante aproximadamente 8 minutos, manteniendo la oxigenación mediante un catéter de insuflación. Esta prueba respalda el diagnóstico de muerte cerebral cuando se determina un aumento de la PaCO 2 superior a 20 mmHg en comparación con el valor inicial o un nivel de PaCO 2 superior a 60 mmHg al final de la prueba. En nuestra serie de casos, la implementación de la tomografía de impedancia eléctrica (EIT) reveló que la prueba de apnea con presión positiva continua (CPAPAT) mitiga eficazmente el colapso pulmonar. Este enfoque resulta en una mejora en la tensión pulmonar en comparación con la desconexión de iMV, demostrando su relevancia en el contexto de potenciales donantes de pulmones.


Asunto(s)
Impedancia Eléctrica , Mediciones del Volumen Pulmonar , Humanos , Masculino , Femenino , Mediciones del Volumen Pulmonar/métodos , Persona de Mediana Edad , Apnea/fisiopatología , Muerte Encefálica/fisiopatología , Muerte Encefálica/diagnóstico , Muerte Encefálica/diagnóstico por imagen , Adulto , Tomografía/métodos , Presión de las Vías Aéreas Positiva Contínua , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Anciano
5.
BMJ Open Respir Res ; 11(1)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38663888

RESUMEN

OBJECTIVE: This study aimed to investigate the utility of CT quantification of lung volume for predicting critical outcomes in COVID-19 patients. METHODS: This retrospective cohort study included 1200 hospitalised patients with COVID-19 from 4 hospitals. Lung fields were extracted using artificial intelligence-based segmentation, and the percentage of the predicted (%pred) total lung volume (TLC (%pred)) was calculated. The incidence of critical outcomes and posthospitalisation complications was compared between patients with low and high CT lung volumes classified based on the median percentage of predicted TLCct (n=600 for each). Prognostic factors for residual lung volume loss were investigated in 208 patients with COVID-19 via a follow-up CT after 3 months. RESULTS: The incidence of critical outcomes was higher in the low TLCct (%pred) group than in the high TLCct (%pred) group (14.2% vs 3.3%, p<0.0001). Multivariable analysis of previously reported factors (age, sex, body mass index and comorbidities) demonstrated that CT-derived lung volume was significantly associated with critical outcomes. The low TLCct (%pred) group exhibited a higher incidence of bacterial infection, heart failure, thromboembolism, liver dysfunction and renal dysfunction than the high TLCct (%pred) group. TLCct (%pred) at 3 months was similarly divided into two groups at the median (71.8%). Among patients with follow-up CT scans, lung volumes showed a recovery trend from the time of admission to 3 months but remained lower in critical cases at 3 months. CONCLUSION: Lower CT lung volume was associated with critical outcomes, posthospitalisation complications and slower improvement of clinical conditions in COVID-19 patients.


Asunto(s)
COVID-19 , Mediciones del Volumen Pulmonar , Pulmón , SARS-CoV-2 , Tomografía Computarizada por Rayos X , Humanos , COVID-19/diagnóstico por imagen , COVID-19/epidemiología , Masculino , Femenino , Estudios Retrospectivos , Anciano , Persona de Mediana Edad , Japón/epidemiología , Mediciones del Volumen Pulmonar/métodos , Pulmón/diagnóstico por imagen , Pronóstico , Estudios de Cohortes , Anciano de 80 o más Años
7.
Crit Care ; 28(1): 142, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38689313

RESUMEN

RATIONALE: End-expiratory lung volume (EELV) is reduced in mechanically ventilated patients, especially in pathologic conditions. The resulting heterogeneous distribution of ventilation increases the risk for ventilation induced lung injury. Clinical measurement of EELV however, remains difficult. OBJECTIVE: Validation of a novel continuous capnodynamic method based on expired carbon dioxide (CO2) kinetics for measuring EELV in mechanically ventilated critically-ill patients. METHODS: Prospective study of mechanically ventilated patients scheduled for a diagnostic computed tomography exploration. Comparisons were made between absolute and corrected EELVCO2 values, the latter accounting for the amount of CO2 dissolved in lung tissue, with the reference EELV measured by computed tomography (EELVCT). Uncorrected and corrected EELVCO2 was compared with total CT volume (density compartments between - 1000 and 0 Hounsfield units (HU) and functional CT volume, including density compartments of - 1000 to - 200HU eliminating regions of increased shunt. We used comparative statistics including correlations and measurement of accuracy and precision by the Bland Altman method. MEASUREMENTS AND MAIN RESULTS: Of the 46 patients included in the final analysis, 25 had a diagnosis of ARDS (24 of which COVID-19). Both EELVCT and EELVCO2 were significantly reduced (39 and 40% respectively) when compared with theoretical values of functional residual capacity (p < 0.0001). Uncorrected EELVCO2 tended to overestimate EELVCT with a correlation r2 0.58; Bias - 285 and limits of agreement (LoA) (+ 513 to - 1083; 95% CI) ml. Agreement improved for the corrected EELVCO2 to a Bias of - 23 and LoA of (+ 763 to - 716; 95% CI) ml. The best agreement of the method was obtained by comparison of corrected EELVCO2 with functional EELVCT with a r2 of 0.59; Bias - 2.75 (+ 755 to - 761; 95% CI) ml. We did not observe major differences in the performance of the method between ARDS (most of them COVID related) and non-ARDS patients. CONCLUSION: In this first validation in critically ill patients, the capnodynamic method provided good estimates of both total and functional EELV. Bias improved after correcting EELVCO2 for extra-alveolar CO2 content when compared with CT estimated volume. If confirmed in further validations EELVCO2 may become an attractive monitoring option for continuously monitor EELV in critically ill mechanically ventilated patients. TRIAL REGISTRATION: clinicaltrials.gov (NCT04045262).


Asunto(s)
Capnografía , Enfermedad Crítica , Mediciones del Volumen Pulmonar , Humanos , Masculino , Femenino , Enfermedad Crítica/terapia , Estudios Prospectivos , Persona de Mediana Edad , Anciano , Mediciones del Volumen Pulmonar/métodos , Capnografía/métodos , Respiración Artificial/métodos , COVID-19 , Tomografía Computarizada por Rayos X/métodos , Adulto
9.
Kyobu Geka ; 77(2): 83-86, 2024 Feb.
Artículo en Japonés | MEDLINE | ID: mdl-38459855

RESUMEN

A 59-year-old male patient was referred to our hospital for further examinations and treatment due to an abnormal shadow detected in his left lower lung lobe on computed tomography. The patient was diagnosed with intralobar pulmonary sequestration and scheduled for an operation. During the surgery, after resection of the aberrant artery, indocyanine green was intravenously injected, and the border between normal lung and sequestrated lung was clearly identified by an infrared thoracoscope. Subsequently, wedge resection was performed, and the patient was discharged on postoperative day 5. Spirometry performed 6 months after the surgery indicated that the patient's lung function was well-preserved compared to the preoperative status.


Asunto(s)
Secuestro Broncopulmonar , Procedimientos Quirúrgicos Pulmonares , Masculino , Humanos , Persona de Mediana Edad , Secuestro Broncopulmonar/diagnóstico por imagen , Secuestro Broncopulmonar/cirugía , Toracoscopios , Pulmón , Mediciones del Volumen Pulmonar
10.
Int J Sports Physiol Perform ; 19(5): 463-470, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38412852

RESUMEN

PURPOSE: To investigate the effects of repeated-sprint training with voluntary hypoventilation at low (RSH-VHL) and high (RS-VHH) lung volume on repeated-sprint ability (RSA) in female athletes. METHODS: Over a 6-week period, 24 female soccer players completed 12 sessions of repeated 30-m running sprints with end-expiratory breath holding (RSH-VHL, n = 8), end-inspiratory breath holding (RS-VHH, n = 8), or unrestricted breathing (RS-URB, n = 8). Before and after training, a running RSA test consisting of performing 30-m all-out sprints until exhaustion was implemented. RESULTS: From before to after training, the number of sprints completed during the RSA test was increased in both RSH-VHL (19.3 [0.9] vs 22.6 [0.9]; P < .01) and RS-VHH (19.3 [1.5] vs 20.5 [1.7]; P < .01) but not in RS-URB (19.4 [1.3] vs 19.5 [1.7]; P = .67). The mean velocity and the percentage decrement score calculated over sprints 1 to 17 were, respectively, higher (82.2% [1.8%] vs 84.6% [2.1%] of maximal velocity) and lower (23.7% [3.1%] vs 19.4% [3.2%]) in RSH-VHL (P < .01), whereas they remained unchanged in RS-VHH and RS-URB. The mean arterial oxygen saturation recorded during training at the end of the sprints was lower in RSH-VHL (92.1% [0.4%]) than in RS-VHH (97.3% [0.1%]) and RS-URB (97.8% [0.1%]). CONCLUSIONS: This study shows that female athletes can benefit from the RSH-VHL intervention to improve RSA. The performance gains may have been limited by the short sprinting distance with end-expiratory breath holding, which provoked only moderate hypoxemia. The increase in the number of sprints in RS-VHH seems to show that factors other than hypoxia may have played a role in RSA improvement.


Asunto(s)
Rendimiento Atlético , Contencion de la Respiración , Acondicionamiento Físico Humano , Carrera , Fútbol , Humanos , Femenino , Fútbol/fisiología , Rendimiento Atlético/fisiología , Carrera/fisiología , Acondicionamiento Físico Humano/métodos , Adulto Joven , Hipoventilación , Consumo de Oxígeno , Mediciones del Volumen Pulmonar
11.
Respirology ; 29(5): 387-395, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38320863

RESUMEN

BACKGROUND AND OBJECTIVE: The identification of progression in patients with fibrosing non-idiopathic pulmonary fibrosis (IPF) interstitial lung diseases (ILDs) represents an ongoing clinical challenge. Lung function decline alone may have significant limitations in the detection of clinically significant progression. We hypothesized that longitudinal changes of 6-min walk distance (6MWD) from baseline, simultaneously considered with measures of lung function, may independently predict survival and identifying clinically significant progression of disease. METHODS: Forced vital capacity (FVC), diffusing lung capacity (DLCO) and 6MWD were considered both at baseline and at 1 year in a discovery cohort (n = 105) and in a validation cohort (n = 138) from different centres. The primary endpoint was lung transplant (LTx)-free survival. RESULTS: Average follow-up was 3 years in both cohorts. Combined incidence of deaths and LTx was 29% and 21%, respectively. No collinearity and no strong correlations were observed among FVC, DLCO and 6MWD longitudinal changes. While age, gender and BMI were not significant, 6MWD decline ≥24 m predicted LTx-free-survival significantly and independently from FVC and DLCO declines, with high sensitivity and specificity, in both the discovery and the validation cohorts. Although FVC and DLCO declines remained significant predictors of LTx-free survival, 6MWD decline was more accurate than the proposed ATS/ERS/JRS/ALAT functional criteria. Results were confirmed after stratifying patients by baseline FVC. CONCLUSION: Longitudinal declines of 6MWD are associated with poor survival in fibrosing ILDs across a wide range of baseline severity, with high accuracy. 6MWD longitudinal decline is largely independent from lung function decline and may be integrated into the routine assessment of progression.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Trasplante de Pulmón , Humanos , Pulmón/cirugía , Enfermedades Pulmonares Intersticiales/diagnóstico , Enfermedades Pulmonares Intersticiales/cirugía , Enfermedades Pulmonares Intersticiales/etiología , Capacidad Vital , Mediciones del Volumen Pulmonar , Trasplante de Pulmón/efectos adversos , Progresión de la Enfermedad
12.
Respir Care ; 69(3): 366-375, 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38416659

RESUMEN

BACKGROUND: Lung hyperinflation is a typical clinical feature of patients with COPD. Given the association between breathing at elevated lung volumes and the manifestation of severe debilitating symptoms, therapeutic interventions such as positive expiratory pressure (PEP) therapy and its variations (temporary, oscillatory) have been devised to mitigate lung hyperinflation. However, the efficacy of these interventions remains to be conclusively demonstrated. METHODS: A systematic review with meta-analysis of randomized trials was conducted following the PRISMA guidelines. Seven databases were screened with no date or language restriction. Two authors independently applied eligibility criteria and assessed the risk of bias of included studies using the Cochrane risk-of-bias tool. Outcomes were lung hyperinflation measures detected through changes in inspiratory capacity (IC), functional residual capacity (FRC), total lung capacity (TLC), and residual volume (RV), as well as FEV1, FVC, dyspnea, and physical capacity. Pooled standardized mean differences (SMDs) or mean differences (MDs) and 95% CI were calculated using a random-effects model. RESULTS: Seven trials, all with a high risk of bias, were included. Compared to control group, RV significantly decreased (4 studies, n = 231; SMD -0.42 [95% CI -0.77 to -0.08], P = .02), dyspnea improved (n = 321, SMD -1.17 [95% CI -1.68 to -0.66], P < .001), and physical capacity increased (5 studies, n = 311; MD 30.1 [95% CI 19.2-41.0] m, P < .001) with PEP therapy. There was no significant difference between PEP therapy and the control group in TLC, FVC, or FEV1. Only one study reported changes in inspiratory capacity as well as FRC. CONCLUSIONS: In patients with COPD, the effect of PEP therapy on lung hyperinflation is unclear owing to the non-consistent change in lung hyperinflation outcomes, insufficient data, and lack of high-quality trials. Dyspnea and physical capacity might improve with PEP therapy.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Humanos , Mediciones del Volumen Pulmonar , Capacidad Pulmonar Total , Volumen Residual , Disnea/etiología , Disnea/terapia , Disnea/diagnóstico , Volumen Espiratorio Forzado
13.
Adv Physiol Educ ; 48(2): 279-283, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38299212

RESUMEN

Here we demonstrate how data from the clinical pulmonary function lab can help students learn about the principle of airway-parenchymal interdependence. We examined the relationship between airway conductance (Gaw) and lung volume (thoracic gas volume, TGV) in 48 patients: 17 healthy; 20 with emphysema, expected to have reduced airway-parenchymal interdependence; and 11 with pulmonary fibrosis, expected to have increased airway-parenchymal interdependence. Our findings support these expectations, with the slope of Gaw vs. TGV being steeper among those with pulmonary fibrosis and flatter among those with emphysema, compared to the slope of the healthy group. This type of analytic approach, using real-world patient data readily available from any pulmonary function laboratory, can be used to explore other fundamental principles of respiratory physiology.NEW & NOTEWORTHY This report demonstrates how common data obtained from the clinical pulmonary function testing laboratory can be used to illustrate important principles of respiratory physiology. Here we show how the relationship between airway conductance and lung volume across different disease states reflects intrinsic differences in airway-parenchymal interdependence.


Asunto(s)
Enfisema , Fibrosis Pulmonar , Humanos , Pulmón/fisiología , Mediciones del Volumen Pulmonar , Fenómenos Fisiológicos Respiratorios
14.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38207290

RESUMEN

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Asunto(s)
Atelectasia Pulmonar , Respiración Artificial , Animales , Femenino , Porcinos , Respiración Artificial/métodos , Pulmón/diagnóstico por imagen , Mediciones del Volumen Pulmonar , Atelectasia Pulmonar/diagnóstico por imagen , Atelectasia Pulmonar/terapia , Perfusión , Oxígeno
15.
J Clin Monit Comput ; 38(2): 539-551, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38238635

RESUMEN

Tidal volume (TV) monitoring breath-by-breath is not available at bedside in non-intubated patients. However, TV monitoring may be useful to evaluate the work of breathing. A non-invasive device based on bioimpedance provides continuous and real-time volumetric tidal estimation during spontaneous breathing. We performed a prospective study in healthy volunteers aimed at evaluating the accuracy, the precision and the trending ability of measurements of ExSpiron®Xi as compared with the gold standard (i.e. spirometry). Further, we explored whether the differences between the 2 devices would be improved by the calibration of ExSpiron®Xi with a pre-determined tidal volume. Analysis accounted for the repeated nature of measurements within each subject. We enrolled 13 healthy volunteers, including 5 men and 8 women. Tidal volume, TV/ideal body weight (IBW) and respiratory rate (RR) measured with spirometer (TVSpirometer) and with ExSpiron®Xi (TVExSpiron) showed a robust correlation, while minute ventilation (MV) showed a weak correlation, in both non/calibrated and calibrated steps. The analysis of the agreement showed that non-calibrated TVExSpiron underestimated TVspirometer, while in the calibrated steps, TVExSpiron overestimated TVspirometer. The calibration procedure did not reduce the average absolute difference (error) between TVSpirometer and TVExSpiron. This happened similarly for TV/IBW and MV, while RR showed high accuracy and precision. The trending ability was excellent for TV, TV/IBW and RR. The concordance rate (CR) was >95% in both calibrated and non-calibrated measurements. The trending ability of minute ventilation was limited. Absolute error for both calibrated and not calibrated values of TV, TV/IBW and MV accounting for repeated measurements was variably associated with BMI, height and smoking status. Conclusions: Non-invasive TV, TV/IBW and RR estimation by ExSpiron®Xi was strongly correlated with tidal ventilation according to the gold standard spirometer technique. This data was not confirmed for MV. The calibration of the device did not improve its performance. Although the accuracy of ExSpiron®Xi was mild and the precision was limited for TV, TV/IBW and MV, the trending ability of the device was strong specifically for TV, TV/IBW and RR. This makes ExSpiron®Xi a non-invasive monitoring system that may detect real-time tidal volume ventilation changes and then suggest the need to better optimize the patient ventilatory support.


Asunto(s)
Respiración , Masculino , Humanos , Femenino , Estudios Prospectivos , Voluntarios Sanos , Volumen de Ventilación Pulmonar , Mediciones del Volumen Pulmonar/métodos
16.
Magn Reson Med ; 91(6): 2612-2620, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38247037

RESUMEN

PURPOSE: Measure the changes in relative lung water density (rLWD), lung volume, and total lung water content as a function of time after supine body positioning. METHODS: An efficient ultrashort-TE pulse sequence with a yarnball k-space trajectory was used to measure water density-weighted lung images for 25 min following supine body positioning (free breathing, 74-s acquisitions, 3D images at functional residual capacity, 18 time points) in 9 healthy volunteers. Global and regional (10 chest-to-back positions) rLWD, lung volume, and total lung water volume were measured in all subjects at all time points. Volume changes were validated with a nitrogen washout study in 3 participants. RESULTS: Global rLWD increased significantly (p = 0.001) from 31.8 ± 5.5% to 34.8 ± 6.8%, while lung volumes decreased significantly (p < 0.001) from 2390 ± 620 mL to 2130 ± 630 mL over the same 25-min interval. Total lung water volume decreased slightly from 730 ± 125 mL to 706 ± 126 mL (p = 0.028). There was a significant chest-to-back gradient in rLWD (20.7 ± 4.6% to 39.9 ± 6.1%) at all time points with absolute increases of 1.8 ± 1.2% at the chest and 5.4 ± 1.9% at the back. Nitrogen washout studies yielded a similar reduction in lung volume (12.5 ± 0.9%) and time course following supine positioning. CONCLUSION: Lung volumes during tidal breathing decrease significantly over tens of minutes following supine body positioning, with corresponding increases in lung water density (9.2 ± 4.4% relative increase). The total volume of lung water is slightly reduced over this interval (3.3 ± 4.0% relative change). Evaluation of rLWD should take time after supine positioning, and more generally, all sources of lung volume changes should be taken into consideration to avoid significant bias.


Asunto(s)
Pulmón , Posicionamiento del Paciente , Humanos , Pulmón/diagnóstico por imagen , Mediciones del Volumen Pulmonar , Respiración , Nitrógeno , Posición Supina
17.
Respir Res ; 25(1): 4, 2024 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-38178216

RESUMEN

RATIONALE: Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES: In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS: In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS: We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS: The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.


Asunto(s)
Ventilación de Alta Frecuencia , Recien Nacido Extremadamente Prematuro , Humanos , Recién Nacido , Oscilometría , Pulmón , Mediciones del Volumen Pulmonar/métodos , Ventilación de Alta Frecuencia/métodos
18.
J Perinatol ; 44(2): 266-272, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38007593

RESUMEN

OBJECTIVE: To investigate a novel servo pressure (SP) setting during high-frequency jet ventilation (HFJV) for a lung protective strategy in a neonatal model of acute respiratory distress. STUDY DESIGN: Comparison of efficacy between variable (standard) and fixed SP settings in a randomized animal study using rabbits (n = 10, mean weight = 1.80 kg) with surfactant deficiency by repeated lung lavages. RESULTS: Rabbits in the fixed SP group had greater peak inspiratory pressure, SP, minute volume, pH, and PaO2, and lower PaCO2 after lung lavage than the variable SP group. Lung volume monitoring with electrical impedance tomography showed that fixed SP reduced the decline of the global lung tidal variation at 30 min after lung lavage (-17.4% from baseline before lavage) compared to variable SP (-44.9%). CONCLUSION: HFJV with fixed SP significantly improved gas exchange and lung volumes compared to variable SP. Applying a fixed SP may have important clinical implications for patients receiving HFJV.


Asunto(s)
Ventilación con Chorro de Alta Frecuencia , Ventilación de Alta Frecuencia , Surfactantes Pulmonares , Animales , Humanos , Conejos , Tensoactivos , Pulmón , Mediciones del Volumen Pulmonar , Respiración Artificial/métodos
19.
Korean J Anesthesiol ; 77(1): 115-121, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37211764

RESUMEN

BACKGROUND: Alveoli tend to collapse in patients with acute respiratory distress syndrome (ARDS). Endotracheal aspiration may increase alveolar collapse due to the loss of end-expiratory lung volume (EELV). We aimed to compare the loss of EELV after open and closed suction in patients with ARDS. METHODS: This randomized crossover study included 20 patients receiving invasive mechanical ventilation for ARDS. Open and closed suction were applied in a random order. Lung impedance was measured using electric impedance tomography. The change in end-expiratory lung impedance end of suction and at 1, 10, 20, and 30 min after suction, was used to represent the change in EELV. Arterial blood gas analyses and ventilatory parameters such as the plateau pressure (Pplat), driving pressure (Pdrive), and compliance of the respiratory system (CRS) were also recorded. RESULTS: Less volume loss was noted after closed suction than after open suction (mean ΔEELI: -2661 ± 1937 vs. -4415 ± 2363; mean difference: -1753; 95% CI [-2662, -844]; P = 0.001). EELI returned to baseline 10 min after closed suction but did not return to baseline even 30 min after open suction. After closed suction, the Pplat and Pdrive decreased while the CRS increased. Conversely, the Pplat and Pdrive increased while the CRS decreased after open suction. CONCLUSIONS: Endotracheal aspiration may result in alveolar collapse due to loss of EELV. Given that closed suction is associated with less volume loss at end-expiration without worsening ventilatory parameters, it should be chosen over open suction in patients with ARDS.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Humanos , Respiración con Presión Positiva/métodos , Estudios Cruzados , Mediciones del Volumen Pulmonar , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/terapia
20.
Eur Radiol ; 34(3): 1524-1533, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37644150

RESUMEN

OBJECTIVES: To develop a mediastinal shift angle (MSA) measurement method applicable to right-sided congenital diaphragmatic hernia (RCDH) in fetal MRI and to validate the predictive value of MSA in RCDH. METHODS: Twenty-seven fetuses with isolated RCDH and 53 controls were included in our study. MSA was measured on MRI axial image at the level of four-chamber view of the fetal heart. The angle between the sagittal midline landmark line and the left boundary landmark line touching tangentially the lateral wall of the left ventricle was used to quantify MSA for RCDH. Appropriate statistical analyses were performed to determine whether MSA can be regarded as a valid predictive tool for postnatal outcomes. Furthermore, predictive performance of MSA was compared with that of lung area to head circumference ratio (LHR), observed/expected LHR (O/E LHR), total fetal lung volume (TFLV), and observed/expected TFLV (O/E TFLV). RESULTS: MSA was significantly higher in the RCDH group than in the control group. MSA, LHR, O/E LHR, TFLV, and O/E TFLV were all correlated with postnatal survival, pulmonary hypertension (PH), and extracorporeal membrane oxygenation (ECMO) therapy (p < 0.05). Value of the AUC demonstrated good predictive performance of MSA for postnatal survival (0.901, 95%CI: (0.781-1.000)), PH (0.828, 95%CI: (0.661-0.994)), and ECMO therapy (0.813, 95%CI: (0.645-0.980)), which was similar to O/E TFLV but slightly better than TFLV, O/E LHR, and LHR. CONCLUSIONS: We developed a measurement method of MSA for RCDH for the first time and demonstrated that MSA could be used to predict postnatal survival, PH, and ECMO therapy in RCDH. CLINICAL RELEVANCE STATEMENT: Newly developed MRI assessment method of fetal MSA in RCDH offers a simple and effective risk stratification tool for patients with RCDH. KEY POINTS: • We developed a measurement method of mediastinal shift angle for right-sided congenital diaphragmatic hernia for the first time and demonstrated its feasibility and reproducibility. • Mediastinal shift angle can predict more prognostic information other than survival in right-sided congenital diaphragmatic hernia with good performance. • Mediastinal shift angle can be used as a simple and effective risk stratification tool in right-sided congenital diaphragmatic hernia to improve planning of postnatal management.


Asunto(s)
Hernias Diafragmáticas Congénitas , Hipertensión Pulmonar , Embarazo , Femenino , Humanos , Hernias Diafragmáticas Congénitas/diagnóstico por imagen , Hernias Diafragmáticas Congénitas/terapia , Pulmón/diagnóstico por imagen , Mediciones del Volumen Pulmonar/métodos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética , Medición de Riesgo , Ultrasonografía Prenatal , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA